gunicorn 信号处理(SIGHUP,SIGUSR2)

Posted xybaby

tags:

篇首语:本文由小常识网(cha138.com)小编为大家整理,主要介绍了gunicorn 信号处理(SIGHUP,SIGUSR2)相关的知识,希望对你有一定的参考价值。

 
这篇文章中,提到了Master进程对信号的处理函数,其中有两个信号比较有意思。
SIGHUP:用来热更新(Reload)应用
SIGUSR2:用来在线升级(upgrade on the fly)gunicorn
 
下面来详细看一下:
 
SIGHUP
    Reload the configuration, start the new worker processes with a new configuration and gracefully shutdown older workers
SIGUP对应的信号处理函数是Arbiter.reload。简化后的核心代码如下:
 1     def reload(self):
 2         old_address = self.cfg.address
 3  
 4         # reload conf,重新加载配置
 5         self.app.reload()
 6         self.setup(self.app)
 7  
 8         # reopen log files
 9         self.log.reopen_files()
10  
11         # do we need to change listener ?,处理监听端口变化的情况
12         if old_address != self.cfg.address:
13             # close all listeners
14             [l.close() for l in self.LISTENERS]
15             # init new listeners
16             self.LISTENERS = create_sockets(self.cfg, self.log)
17             listeners_str = ",".join([str(l) for l in self.LISTENERS])
18             self.log.info("Listening at: %s", listeners_str)
19  
20         # spawn new workers,启动新的Worker(数量和类型来自新的配置)
21         for i in range(self.cfg.workers):
22             self.spawn_worker()
23  
24         # manage workers,这里会kill掉原来的Worker
25         self.manage_workers()

 

  在上面的引用中提到,会“优雅”(graceful)地kill掉老的worker进程。实现也很简单,Arbiter为每一个fork出的worker进程设置一个自增的“worker_age”,worker中这个属性越小,表明这个worker越老。在manage_workers中,如果已经启动的worker进程数量大于配置中的数量,那么会kill掉比较老的worker进程。代码如下
 1     def manage_workers(self):
 2         """\\
 3         Maintain the number of workers by spawning or killing
 4         as required.
 5         """
 6         if len(self.WORKERS.keys()) < self.num_workers:
 7             self.spawn_workers()
 8  
 9         workers = self.WORKERS.items()
10         workers = sorted(workers, key=lambda w: w[1].age) # 按worker的age顺序排序
11         while len(workers) > self.num_workers: # num_workers是配置的worker数量
12             (pid, _) = workers.pop(0)
13             self.kill_worker(pid, signal.SIGTERM)

 

SIGUSR2
Upgrade the Gunicorn on the fly. A separate TERM signal should be used to kill the old process.
  对应的信号处理函数是Arbiter.reexec,该函数会重新fork出新的master-workers进程,但不会影响到原来的master,worker进程,所以上面提到需要将原来的进程kill掉。
 1     def reexec(self):
 2         """\\
 3         Relaunch the master and workers.
 4         """
 5         if self.reexec_pid != 0:
 6             self.log.warning("USR2 signal ignored. Child exists.")
 7             return
 8  
 9         if self.master_pid != 0:
10             self.log.warning("USR2 signal ignored. Parent exists")
11             return
12  
13         master_pid = os.getpid()
14         self.reexec_pid = os.fork()
15         if self.reexec_pid != 0:
16             return
17  
18         self.cfg.pre_exec(self)
19  
20         environ = self.cfg.env_orig.copy()
21         fds = [l.fileno() for l in self.LISTENERS]
22         environ[\'GUNICORN_FD\'] = ",".join([str(fd) for fd in fds]) # 设置了一些环境变量,用来区分是正常启动gunicorn还是通过fork重新启动。
23         environ[\'GUNICORN_PID\'] = str(master_pid)
24  
25         os.chdir(self.START_CTX[\'cwd\'])
26  
27         # exec the process using the original environnement
28         os.execvpe(self.START_CTX[0], self.START_CTX[\'args\'], environ)

 

下面做一下实验,两个终端,1号终端运行代码,2号终端发送信号。
step1
1号终端启动gunirorn: gunicorn -w 2 gunicorn_app:app
2号终端查看python进程: ps -ef | grep python,
 
1号终端输出
[2017-01-19 15:21:23 +0000] [6166] [INFO] Starting gunicorn 19.6.0
[2017-01-19 15:21:23 +0000] [6166] [INFO] Listening at: http://127.0.0.1:8000 (6166)
[2017-01-19 15:21:23 +0000] [6166] [INFO] Using worker: sync
[2017-01-19 15:21:23 +0000] [6171] [INFO] Booting worker with pid: 6171
[2017-01-19 15:21:23 +0000] [6172] [INFO] Booting worker with pid: 6172
 
2号终端输出
hzliumi+  6166  5721  0 15:21 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6171  6166  0 15:21 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6172  6166  0 15:21 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
 
可以看到,master进程的PID是6166,然后两个worker进程的pid分别是6171、6172. 下面需要用到master进程的PID
 
step2
2号终端发送信号:kill -SIGUSR2 6166 , 然后查看python进程
 
1号终端追加输出
[2017-01-19 15:27:08 +0000] [6166] [INFO] Handling signal: usr2
[2017-01-19 15:27:08 +0000] [6629] [INFO] Starting gunicorn 19.6.0
[2017-01-19 15:27:08 +0000] [6629] [INFO] Listening at: http://127.0.0.1:8000 (6629)
[2017-01-19 15:27:08 +0000] [6629] [INFO] Using worker: sync
[2017-01-19 15:27:08 +0000] [6634] [INFO] Booting worker with pid: 6634
[2017-01-19 15:27:08 +0000] [6635] [INFO] Booting worker with pid: 6635
 
2号终端输出
hzliumi+  6166  5721  0 15:21 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6171  6166  0 15:21 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6172  6166  0 15:21 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6629  6166  3 15:27 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6634  6629  0 15:27 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6635  6629  0 15:27 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
 
从1号终端可以看出,基本是重新启动了gunicorn,不过从2号终端输出可以看到,新的master进程(pid 6629)是老的master进程(pid 6166)的子进程
 
step3
    2号终端发送信号:kill -SIGTERM 6166 , 稍等几秒后查看python进程:
 
1号终端追加输出
[2017-01-19 15:29:42 +0000] [6166] [INFO] Handling signal: term
[2017-01-19 15:29:42 +0000] [6171] [INFO] Worker exiting (pid: 6171)
[2017-01-19 15:29:42 +0000] [6172] [INFO] Worker exiting (pid: 6172)
[2017-01-19 15:29:42 +0000] [6166] [INFO] Shutting down: Master
[2017-01-19 15:29:42 +0000] [6629] [INFO] Master has been promoted.
 
2号终端输出
hzliumi+  6629     1  0 15:27 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6634  6629  0 15:27 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
hzliumi+  6635  6629  0 15:27 pts/0    00:00:00 /usr/bin/python /usr/local/bin/gunicorn -w 2 gunicorn_app:app
 
可以看到,老的master进程(6166)及其fork出的worker子进程(pid分别是6171、6172)已经被kill掉了
 
 
 
references:

以上是关于gunicorn 信号处理(SIGHUP,SIGUSR2)的主要内容,如果未能解决你的问题,请参考以下文章

c_cpp C,SIGINT,SIGALRM,SIGHUP中的Unix信号处理示例......

7. 信号的处理问题

Linux信号:孩子没有收到

linux中SIGHUP与nohup的关系

在 nginx/gunicorn/django Web 架构中有效处理长时间运行的 HTTP 连接

Gunicorn 在多处理进程和工作进程之间共享内存