xdebug 一直报错 upstream timed out (110: Connection timed out) while reading response header from upstre
Posted
tags:
篇首语:本文由小常识网(cha138.com)小编为大家整理,主要介绍了xdebug 一直报错 upstream timed out (110: Connection timed out) while reading response header from upstre相关的知识,希望对你有一定的参考价值。
本地主机(Windows环境192.168.66.1)访问虚拟机(192.168.66.139)里面的搭建的php环境(系统centos6.5版本,php版本是5.5.30 ,xdebug 2.4.0),通过命令行pecl install xdebug安装的xdebug,
在php.ini配置xdebug
[Xdebug]
zend_extension=/usr/local/php/lib/php/extensions/no-debug-non-zts-20121212/xdebug.so
xdebug.auto_trace = On
xdebug.idekey = phpstorm
xdebug.remote_connect_back = On
xdebug.auto_trace = On
xdebug.show_exception_trace = On
xdebug.remote_autostart = On
xdebug.remote_enable = On
xdebug.collect_vars = On
xdebug.collect_return = On
xdebug.collect_params = 1
xdebug.remote_handler=dbgp
xdebug.remote_host=127.0.0.1
xdebug.remote_port=9001
xdebug.profiler_enable=On
xdebug.trace_output_dir = "/tmp/xdebug2222/"
xdebug.profiler_output_dir = "/tmp/xdebug/"
xdebug.remote_mode = req
反问页面index.php,页面一直卡死,查看nginx错误日志,发现一直有upstream timed out (110: Connection timed out) while reading response header from upstream
php-fpm一直报超时的错误,应该是php-fpm返回请求超过了设置的时间,但是一直不知道为什么会报错,脚本也没问题,
发现xdebug.remote_connect_back = On把这行注释掉之后,就没问题了,邪门啊。
官网地址:https://xdebug.org/docs/all_settings#remote_connect_back
官网给出的这个这个参数的解释是
xdebug.remote_connect_back
Type: boolean, Default value: 0, Introduced in Xdebug > 2.1
If enabled, the xdebug.remote_host setting is ignored and Xdebug will try to connect to the client that made the HTTP request. It checks the $_SERVER[‘REMOTE_ADDR‘] variable to find out which IP address to use. Please note that there is no filter available, and anybody who can connect to the webserver will then be able to start a debugging session, even if their address does not match xdebug.remote_host.
大概意思是,设置了这个参数之后,xdebug返回数据时就不会只返回给xdebug.remote_host参数设置的IP了,任何ip请求都会返回数据,这样就可以多人共享这台服务器的php xdebug环境了。
不过还是没知道解决办法,不知道为什么。。
以上是关于xdebug 一直报错 upstream timed out (110: Connection timed out) while reading response header from upstre的主要内容,如果未能解决你的问题,请参考以下文章
Nginx 高并发下报错 connect() failed (110: Connection timed out) while connecting to upstream
压测引起的 nginx报错 502 no live upstreams while connecting to upstream解决