One user feedback: I have KTM Bench ECU programmer to test with different ecms
And always with the same message "Bosch MEDC17 (TC1724 /1728 / 1767 / 1782 / 1784 / 1797) Flash identification, entering reprogramming mode failure"
I have tested the same connection with another j2534 interface
And can connect with ecm obviously can‘t read
the ecu type is 1766.
Attach several images of the Bosch ECU type & its internal pcb, the connection diagram, the error messages:
obdexpress.co.uk engineer solution:
The cpu is tc1767,but you connect as tc1766,so your connection is wrong.
Finally, the problem is solved!
Here BOSCH MEV17.4.2 IROM TC1767 PSA 1033:
PLUGIN 286
DIRECT CONNECTION WITH TRASDATA SYSTEM
In order to perform the Trasdata direct connection with free wirings it will be necessary to
connect the POL4 pin and DSDO signal too. DSDO is the yellow wire on BDM connector of the
universal adapter F34TD003.
DIRECT CONNECTION WITH NEWGWNIUS SYSTEM
In order to perform the NewGenius free wires connection you need the F32GN037
or F32GN037-B cable. BLUE wire = CNF1, GREY wire = BOOT
DIRECT CONNECTION
DIMA CONNECTION
Connect the 2 boot pin to the programming lay-by pin n. 10. Moreover it is necessary to
solder a third wire that must be connected to the CNF1 clamp on the DIMA.
Credits to www.obdexpress.co.uk
以上是关于How to solve KTM Bench identified Bosch MEDC17 ECU failure的主要内容,如果未能解决你的问题,请参考以下文章
Needleless Injection Site -How To Solve: Stuck Needleless Connector
how to check and solve port conflict in windows10
how to solve gpg key error for archlinuxcn
How to solve SD Connect C4 dead, not power up
How to solve java.net.SocketTimeoutException:60000millis problem in HDFS