Power Off Notification (PON) SHORT & LONG ---the difference

Posted aspirs

tags:

篇首语:本文由小常识网(cha138.com)小编为大家整理,主要介绍了Power Off Notification (PON) SHORT & LONG ---the difference相关的知识,希望对你有一定的参考价值。

Power Off Notification (PON)

1) Short Power Off Notification: Host shall expect a shorter timeout when this command is executed. The max value is defined by EXT_CSD[248] (GENERIC_CMD6_TIME, default is 0x19 = 250ms)
2) Long Power Off Notification: Host shall expect a longer timeout when this command is executed. The max value is defined by EXT_CSD[247] (POWER_OFF_LONG_TIME, default is 0xFF = 2550ms)
For the Short Power Off Notification, the device can only back up important information due to short power off time. Depending on the host’s judgment, if there is sufficient time, hosts will send a Long Power Off Notification. This provides sufficient time for the device to back up all the cached data. Figure 8 shows the process.

以上是关于Power Off Notification (PON) SHORT & LONG ---the difference的主要内容,如果未能解决你的问题,请参考以下文章

6.3.2Transmit OFF power——翻译

学习linux源码

VM 虚拟机 总是会自动挂起,即使在虚拟系统中使用了power -h off 还是会,如何禁止VM自动挂起?

/proc/kallsyms 中标有“T”的内核符​​号未导出

ESxi命令行查看启动虚机

健身器材power mode是啥意思