参考技术A 查看服务器RAID信息,硬盘是否正常。[root@monitor~]# hpacucli ctrl all show config
Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018042FF0)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (279.4 GB, RAID 1, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)
3)通过hpacucli ctrl all show config detail命令可以详细地查看RAID和硬盘的信息。
[root@monitor ~]# hpacucli ctrl all show config detail
Smart Array P410i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 5001438018042FF0
Cache Serial Number: PBCDH0CRH1FH62
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Chassis Slot:
Hardware Revision: Rev C
Firmware Version: 5.14
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Accelerator Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Array: A
Interface Type: SAS
Unused Space: 0 MB
Status: OK
Logical Drive: 1
Size: 279.4 GB
Fault Tolerance: RAID 1
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Stripe Size: 128 KB
Status: OK
Array Accelerator: Enabled
Unique Identifier: 600508B1001034373220202020200002
Disk Name: /dev/cciss/c0d0
Mount Points: /boot 99 MB
Logical Drive Label: A00ADBD9PR7AMU1472 898D
Mirror Group 0:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
Mirror Group 1:
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)
physicaldrive 1I:1:1
Port: 1I
Box: 1
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD4
Serial Number: ECA1PC80GTS31234
Model: HP EG0300FBDSP
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
physicaldrive 1I:1:2
Port: 1I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD7
Serial Number: PMX6902D
Model: HP EG0300FBDBR
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
HP官方还有一个hpasmcli管理工具,可以很详细查看服务器CPU,内存,处理器,电源等的温度信息。本回答被提问者采纳