阿里云 mysql 无缘无故挂掉

Posted 华裳绕指柔

tags:

篇首语:本文由小常识网(cha138.com)小编为大家整理,主要介绍了阿里云 mysql 无缘无故挂掉相关的知识,希望对你有一定的参考价值。

近期在登录自己博客时,老是报数据库连接失败,然后重启服务器就好了。
但是,重启服务器很耗时间,不方便,不能每次都重启吧
于是远程连接服务器看了一下
原来是数据库服务挂掉了
启动时还报错
于是查看了下错误日志

2016-11-09 08:13:11 12604 [Note] Plugin \'FEDERATED\' is disabled.
2016-11-09 08:13:11 12604 [Note] InnoDB: Using atomics to ref count buffer pool pages
2016-11-09 08:13:11 12604 [Note] InnoDB: The InnoDB memory heap is disabled
2016-11-09 08:13:11 12604 [Note] InnoDB: Mutexes and rw_locks use GCC atomic builtins
2016-11-09 08:13:11 12604 [Note] InnoDB: Memory barrier is not used
2016-11-09 08:13:11 12604 [Note] InnoDB: Compressed tables use zlib 1.2.3
2016-11-09 08:13:11 12604 [Note] InnoDB: Using Linux native AIO
2016-11-09 08:13:11 12604 [Note] InnoDB: Using CPU crc32 instructions
2016-11-09 08:13:11 12604 [Note] InnoDB: Initializing buffer pool, size = 128.0M
InnoDB: mmap(137363456 bytes) failed; errno 12
2016-11-09 08:13:11 12604 [ERROR] InnoDB: Cannot allocate memory for the buffer pool
2016-11-09 08:13:11 12604 [ERROR] Plugin \'InnoDB\' init function returned error.
2016-11-09 08:13:11 12604 [ERROR] Plugin \'InnoDB\' registration as a STORAGE ENGINE failed.
2016-11-09 08:13:11 12604 [ERROR] Unknown/unsupported storage engine: InnoDB
2016-11-09 08:13:11 12604 [ERROR] Aborting

原因是内存不够用了,导致mysql 崩溃
解决办法
修改mysql配置文件

vi /etc/my.cnf

修改如下代码:

[inonodb]
innodb_buffer_pool_size=8MB

把内存改小就好了。
重启MySQL服务

service mysqld restart

参考文章:

InnoDB: mmap(137363456 bytes) failed; errno 12
mysql5.6 无故退出 InnoDB: mmap(137363456 bytes) failed; errno 12
mysql – 启动错误InnoDB: mmap(137363456 bytes) failed; errno 12

以上是关于阿里云 mysql 无缘无故挂掉的主要内容,如果未能解决你的问题,请参考以下文章

一次mysql无缘无故的挂掉,使用innodb_force_recovery修复

阿里云腾讯云无缘国采,中国电信2.17亿中标“国”字头云平台

IIS无故频繁挂掉,高分求助

Mysql挂掉后无法重启,报错pid文件丢失

调用阿里云OSS未释放资源造成的内存溢出

springboot应用无故停止运行killed解决方法