GridView PageIndexChanging 事件未在 UpdatePanel 内触发
Posted
技术标签:
【中文标题】GridView PageIndexChanging 事件未在 UpdatePanel 内触发【英文标题】:GridView PageIndexChanging event is not firing inside UpdatePanel 【发布时间】:2018-03-19 05:27:00 【问题描述】:我的问题没有找到任何解决方案:
GridView 分页事件
gvBanquet_PageIndexChanging
在 UpdatePanel 中时不会触发。
问题代码在这里:
<asp:UpdatePanel ID="UpdatePanel1" runat="server" UpdateMode="Conditional">
<ContentTemplate>
<div class="col-lg-12 table-responsive">
<asp:GridView ID="gvBanquet" runat="server" AutoGenerateColumns="false"
OnRowCommand="gvBanquet_RowCommand" AllowPaging="True" PageSize="5"
EmptyDataText="No record found!" OnPageIndexChanging="gvBanquet_PageIndexChanging"
ShowHeaderWhenEmpty="true">
<Columns>
// here are templates
</Columns>
<PagerStyle CssClass="pagination-ys" />
</asp:GridView>
</div>
<!-- /.col-lg-12 -->
</ContentTemplate>
<Triggers>
<asp:AsyncPostBackTrigger ControlID="gvBanquet" EventName="PageIndexChanging" />
</Triggers>
</asp:UpdatePanel>
这是一个寻呼事件:
protected void gvBanquet_PageIndexChanging(object sender, GridViewPageEventArgs e)
gvBanquet.PageIndex = e.NewPageIndex;
// fill and bind gridview here
我添加了一个断点,但它没有触发。
如何触发分页按钮?
【问题讨论】:
显示您的getdata
代码
@Webruster 我已经编辑了我的问题。
DLBqt.SelectBanquet
代码?
这是一个简单的方法,运行select
语句从数据库中获取记录并返回DataTable。
@Webruster 我已经编辑了问题。
【参考方案1】:
GridView
没有绑定方法,所以我提供了两种方法(两种方法都有效)方法 1:与SqlDataSource
的声明式绑定:
<form id="form1" runat="server">
<%--ScriptManager required by UpdatePanel --%>
<asp:ScriptManager runat="server" ID="sm" />
<div>
<asp:UpdatePanel runat="server" UpdateMode="Conditional">
<ContentTemplate>
<asp:GridView ID="gvProducts" runat="server" AutoGenerateColumns="False" AllowPaging="true" PageSize="5" DataKeyNames="ProductID" DataSourceID="sqlNWind">
<Columns>
<asp:BoundField DataField="ProductID" HeaderText="ProductID" SortExpression="ProductID" />
<asp:BoundField DataField="ProductName" HeaderText="ProductName" SortExpression="ProductName" />
<asp:TemplateField HeaderText="CategoryName" SortExpression="CategoryName">
<ItemTemplate>
<asp:Label ID="Label1" runat="server" Text='<%# Eval("CategoryName") %>'></asp:Label>
</ItemTemplate>
</asp:TemplateField>
</Columns>
</asp:GridView>
<%--Triggers are redundant because GridView is inside the UpdatePanel --%>
</ContentTemplate>
</asp:UpdatePanel>
<asp:SqlDataSource ID="sqlNWind" runat="server" ConnectionString="<%$ ConnectionStrings:NorthwindCnn %>"
SelectCommand="SELECT Products.ProductID, Products.ProductName, Products.CategoryID, Categories.CategoryName FROM Products INNER JOIN Categories ON Products.CategoryID = Categories.CategoryID">
</asp:SqlDataSource>
</div>
</form>
不需要任何代码。
方法2:从代码后面绑定:
.aspx
<form id="form1" runat="server">
<asp:ScriptManager runat="server" ID="sm" />
<div>
<asp:UpdatePanel runat="server" UpdateMode="Conditional">
<ContentTemplate>
<asp:GridView ID="gvProducts" runat="server" OnPageIndexChanging="gvProducts_PageIndexChanging" AutoGenerateColumns="False" AllowPaging="true" PageSize="5" DataKeyNames="ProductID">
<Columns>
<asp:BoundField DataField="ProductID" HeaderText="ProductID" InsertVisible="False" ReadOnly="True" SortExpression="ProductID" />
<asp:BoundField DataField="ProductName" HeaderText="ProductName" SortExpression="ProductName" />
<asp:TemplateField HeaderText="CategoryName" SortExpression="CategoryName">
<ItemTemplate>
<asp:Label ID="Label1" runat="server" Text='<%# Eval("CategoryName") %>'></asp:Label>
</ItemTemplate>
</asp:TemplateField>
</Columns>
</asp:GridView>
</ContentTemplate>
</asp:UpdatePanel>
</div>
</form>
.aspx.vb
Private Sub Page_Load(sender As Object, e As EventArgs) Handles Me.Load
If Not Page.IsPostBack Then
BindProds()''//Bind initial
End If
End Sub
Protected Sub gvProducts_PageIndexChanging(sender As Object, e As GridViewPageEventArgs)
gvProducts.PageIndex = e.NewPageIndex
BindProds()''//Bind when pageIndex changing
End Sub
Private Sub BindProds()
Using cnn As New Data.SqlClient.SqlConnection(ConfigurationManager.ConnectionStrings("NorthwindCnn").ConnectionString)
Using cmd As New Data.SqlClient.SqlCommand("SELECT Products.ProductID, Products.ProductName, Products.CategoryID, Categories.CategoryName FROM Products INNER JOIN Categories ON Products.CategoryID = Categories.CategoryID", cnn)
Dim da As New Data.SqlClient.SqlDataAdapter(cmd)
Dim dt As New Data.DataTable()
da.Fill(dt)
da.Dispose()
gvProducts.DataSource = dt
gvProducts.DataBind()
End Using
End Using
End Sub
代码是VB.NET
。希望OP能翻译成C#
。
【讨论】:
【参考方案2】:没有看到您的getdata
代码的一种可能情况是:
每次更改页面索引时,您都应该阅读用于加载 gridview 的数据集(您的案例 Datatable )。通过这种方式,您可以确保在每个由 gridview 页码触发的单独回发中,都会填充结果。
更新
尝试添加触发器
<Triggers>
<asp:AsyncPostBackTrigger ControlID="gvBanquet" EventName="PageIndexChanging" />
</Triggers>
【讨论】:
@Asif.Ali 请在更新后更新您的问题asp:GridView
没有 AutoPostBack
属性。
@AlexKudryashev 谢谢,修改了我的答案,我忽略了它以上是关于GridView PageIndexChanging 事件未在 UpdatePanel 内触发的主要内容,如果未能解决你的问题,请参考以下文章